MVL: Virology
and Molecular Biology; Cellular
Biology; General
SHARED FACILITIES: General;
Cell & Molecular
Biology
MAINFRAME COMPUTERS
I. MOLECULAR VIROLOGY LABORATORY:
Virology and Molecular Biology:
Perkin Elmer 2000 PCR
thermocycler; Heat Systems W-225R 200 W ultrasonicator
with standard and microtip probes plus cup horn, Biorad
155 tube electrophoresis cell, Biorad tube gel destainer
172, Fisher FB GD 45 Gel Dryer, Lammert 10302 vacuum pump
and cold trap, Fisher vacuum pump, Duerr vacuum pump,
Biorad slab gel dryer 224, Biorad 221 vertical slab cell
with cooling system, Power packs (Canalco, Biorad 400),
Fisher FB 135 power pack, Hoefer Studier gel cells
(SE400) (3 ea.), Hoefer PlateMate washer, UV Products
transilluminator C61, Portable short-wave UV lamp, Hall
productions light box, Beckman SW27, SW41 rotors,
Submarine cell, Fisher Mini submarine cells (FB-MSU-1) (2
ea.), Fisher FB 105 power pack, Biorad Model 160/1.6
power pack, Polaroid CU5 camera and frame, Fisher Biotech
DNA sequencing cells (FB-SEQ-3545) (2 ea.), Fisher FB 600
power pack, Fisher autoradiography cassettes 14x17 in. (5
ea.), Intensifying screens 14 x 17 in. (2 ea.), Fisher
autoradiography cassettes 8 x 10 in. (5 ea.),
Intensifying screens 8 x 10 in. (6 ea.), Boekel
hybridizing ovens (5 cyl. capacity), Millipore 1225
sampling manifold, Amicon ultra filtration cells (200 ml,
50 ml, 10 ml), Eppendorf microcentrifuges (14,000 g) (2 ea.), Fisher MicroV
variable-speed microfuge (7,200 g), Millipore peristaltic
pump, National vacuum oven, EC microdensitometer with
scanning software, Hoefer Mighty Small 4-gel cooled
transphor unit, Fisher FB 570 power pack, Biorad
Transblot apparatus, Biorad Bio-Dot Apparatus, BRL
Hybri-dot blot manifold, Developing tanks and racks for
X-ray films, Beckton-Dickinson Nutator mixer, Bellco
rocker platform; Fisher Biotech gel photo documentation
camera.
Cellular Biology:
IEC Model PR-J
refrigerated centrifuge, IEC Model HN-S bench centrifuge,
Olympus IX70 inverted phase-contrast microscope with
40X,20X, 10X, 4X objective and Nikon FM2 camera back;
Olympus model CK inverted phase microscope with adapter
and camera back; American Optical Phasestar phase
contrast microscope; American Optical Phasestar
dissecting microscopes (4 ea.); American Optical
Phasestar bright field microscope; Bausch & Lomb
dissecting microscope; Bausch & Lomb bright-field
microscope; Nikon F70 camera back with Nikkor 28-80 zoom
Lens mm and AF Micro Nikkor Lens 60 mm plus extension
rings; copy stand; Linde XR-16 liquid nitrogen
refrigerator and Dewar flask, Bellco platform rocker,
Wheaton roller culture apparatus, Napco dual chamber CO2
incubator, Baker horizontal laminar-flow hood, ICC 6-foot
vertical laminar-flow hood, Wescor 5100C vapor pressure
osmometer, Lab-line Imperial II incubator.
General:
PowerMac G4 500 MHz,
PowerBook
G3, PowerBook 3400, PowerMac 8500, Power Macintosh 7100, LW 360 printer, LW310 printer, Epson
Stylus Color 850 printer; UMAX Astra 1220S Scanner with
UMAX UTA-3A transparency adapter; Epson ED-1200C scanner,
several APS external drives, several Zip drives; Haake
circulating water bath, Labline orbital shaker bath, VWR
water bath, Napco water bath, Dry bath units (24-place)
(4 ea.), Corning pH meters (2 ea.), Balance Denver
Instruments XS 410 electronic balance; A&D HR-120
4-digit balance. Fisher scientific AB15 pH meter; Multi-Channel
Pipettes: Rainin Pipetts: P-1000 3 ea.; P-200 3 ea.;
P-100 2 ea.; P-20 5 ea.; P-10 1 ea.; Repeat pipettes (1
µl - 1.25 ml) 1 ea.; (P-200) 1 ea.; Fixed volume (10 µl) 1 ea., So-Low -80°
freezer (5 cu. ft), So-Low -60° freezer (5 cu. ft), Freezer/refrigerators (4 ea.), Chest
type freezer (25 cu. ft), Masterbuilt 36 sq. ft glass
front cold cabinet, Vortex mixers, Magnetic stirrers,
Uniden Geiger counter, Corning Mega-pure distillation
apparatus, Continental de-ionizing system, 3 x 21 qt.
pressure cookers, Sterilizing ovens (2 ea.), Napco drying
oven, microwave ovens.
Dell
Dimension 8200 Desktop: Intel® Pentium® 4
Processor at 1.8GHz, 256MB Dual Channel RDRAM, 21" Flat Panel
displays, drive: 8x/4x/32x CD-RW/DVD.
Dell Dimension 4400 Desktop: Intel® Pentium® 4
Processor at 1.6GHz, 256MB Dual Channel RDRAM, 19" Flat Panel
displays, drive: 8x/4x/32x CD-RW/DVD.
Dell Inspiron 8100: Intel® Pentium® 3 Processor
at 1.2GHz, 512MB RAM, 15" displays monitor.
SHARED FACILITIES: General;
Cell & Molecular
Biology
MAINFRAME COMPUTERS
II. SHARED FACILITIES: (Biological
Sciences; Center for Biotechnology & Genomics):
General:
Biology greenhouse:
8000 sq. ft., Biology walk-in environmental chambers: 8 x
100 sq. ft, Biology USDA-approved animal room: 1500 sq.
ft, Microbiology cold room space: 300 sq. ft., Biology
cold room space: 4 x 100 sq. ft., Microbiology
stockroom/prep-room (800 sq. ft), Electron microscopy
(800 sq. ft.), Walk-In incubators (300 sq. ft.). Several
automatic washers, Several dryers, Several autoclaves,
Departmental water purification system (reverse osmosis
plus deionized water supplied to all labs)
Cell & Molecular Biology:
Beckman J2-21
centrifuge with JA20, JS7, and JS13 rotors plus four
Sorvalls, Beckman L 3-50 ultracentrifuge with SW27, SW41,
and type 70 rotors plus two additional ultracentrifuges,
Beckman LS 6500 multipurpose bench top scintillation
counter (new), Beckman LS 7500 scintillation counter,
Beckman DU-64 UV spectrophotometer, Packard Biosciences
Cobra II Series Cobra Quantum Gamma counter, Scanning
electron microscope, two Transmission electron
microscopes, Ultra-microtome, Freeze-fracture machine,
and Pharmacia FPLC system. Additional advanced equipment
is available at the
Biotechnology and
Genomics Core Facilities operated by the
Institute for Biotechnology and Genomics. These
include: Beckman Gold HPLC system, Milligen 6625
Pro-Sequencer, Milligen Sy-Clone DNA synthesizer, Laser
densitometer, Thermocyclers (5),a
BioRad
Particle Gun,
three
chromatogranphy
systems (a Pharmacia
FPLC,
Perkin-Elmer Biosystems
Biocad Sprint,
and a Dionex
HPLC), Automatic X-ray
developing system, Imagegraphics computerized
slide-making system (Macintosh & Windows), (6) Texas
Tech University has recently acquired five additional DNA
auto-sequencers at the Institute for Biotechnology and Genomics.
MVL: Virology
and Molecular Biology; Cellular
Biology; General
MAINFRAME COMPUTERS
III. TEXAS TECH ACADEMIC COMPUTER
SYSTEM:
VAX and IBM, UNIX, and Sun
systems; Access to Texas Tech University Library Catalog;
Access to literature databases through Texas Tech
University Library; First Search (Medline, Agricola,
BasicBIOSIS, etc.); UnCover; Ideal (On-line journals);
Access to Current Contents (disk form) through
department; WEB GCG (Wisconsin Computer Genetics Group;
WCGG); Access through internet to DNA and protein
analysis tools; National Center for Biotechnology
Information (NCBI); European Bioinformatics Institute
(EBI).
MVL: Virology
and Molecular Biology; Cellular
Biology; General
SHARED FACILITIES: General;
Cell & Molecular
Biology
|